The UNI-T UT-P07A 500MHz Passive Oscilloscope Probe is an essential tool for anyone working with electronic systems, providing accurate and reliable measurements of electrical signals. This high-performance probe features a bandwidth of up to 500MHz, making it suitable for measuring a wide range of signals, from low frequency to high speed digital signals.
The probe comes with a detachable BNC test lead, which allows for easy connection to an oscilloscope or other test equipment. The 10x probe tip provides a sensitivity of 0.1pA/V, enabling the measurement of even the smallest electrical signals. The probe tip is also passive, meaning it does not require an external power source, making it safe and convenient to use.
The UNI-T UT-P07A probe is built with high-quality components, ensuring accurate and precise measurements. It is designed with a low capacitance tip to minimize signal distortion and provide a clear and true representation of the electrical signal. The probe also features a wide dynamic range, with a maximum input voltage of 50V, making it suitable for measuring both small and large signals.
The probe is compact and lightweight, making it easy to transport and use in various environments. It is also robust and durable, with a sturdy design that can withstand the rigors of regular use in a lab or workshop setting. The probe comes with a protective cap to keep the tip clean and free from contamination when not in use.
The UNI-T UT-P07A 500MHz Passive Oscilloscope Probe is a versatile and indispensable tool for electronics engineers, technicians, and hobbyists. It provides accurate and reliable measurements of electrical signals, with a wide bandwidth, high sensitivity, and low capacitance tip. Its compact and durable design makes it a valuable addition to any lab or workshop.
Uni-T UT-P07A 500MHz Passive Oscilloscope Probe: An In-depth Analysis
The Uni-T UT-P07A 500MHz Passive Probe is a popular choice among electronics hobbyists and technicians due to its versatility and affordability. In this analysis, we will discuss the key features, advantages, and disadvantages of this probe to help you make an informed purchasing decision.
1. Features:
- Frequency range: 10Hz to 500MHz
- Bandwidth: DC to 500MHz
- Probe tip types: Interchangeable S probe and Banana probe
- Input impedance: 1M (terminated) and 10M (unterminated)
- Cable length: 1m
2. Advantages:
a. Wide frequency range: The UT-P07A can handle signals up to 500MHz, which is suitable for a broad range of applications.
b. Interchangeable tips: The probe comes with both S and Banana probe tips, allowing users to choose the most appropriate tip for their specific measurement needs.
c. Affordable: Compared to active probes, passive probes are generally more budget-friendly.
d. Durable: The Uni-T UT-P07A is known for its robust construction, making it suitable for heavy usage in various environments.
3. Disadvantages:
a. Limited bandwidth: Although the probe has a wide frequency range, its bandwidth is relatively low, which may affect the accuracy of measurements for high-frequency signals.
b. Requires calibration: Passive probes do not have internal amplification, so they need to be calibrated regularly to ensure accurate measurements.
Conclusion:
The Uni-T UT-P07A 500MHz Passive Probe is a versatile and affordable option for those seeking a wide frequency range and interchangeable tips. However, its limited bandwidth and the need for regular calibration are potential drawbacks. If you require high-accuracy measurements for high-frequency signals, an active probe might be a better choice. On the other hand, if you're on a budget or working with lower-frequency signals, the UT-P07A could be an excellent investment.
Recommendation:
If you're looking for a cost-effective and versatile passive oscilloscope probe for general-purpose applications, the Uni-T UT-P07A 500MHz Passive Probe is a solid choice. However, if you need to measure high-frequency signals with high accuracy, consider investing in an active probe.
Details:
Please consider troubleshooting prior to making a return request. Photos are greatly appreciated. Probe attenuation: 10:1. 47in 120cm in length .
Voltage : 600vpp. Passive probe. Band width mhz: 500mhz.
specifications oscillovectscopes:
brand: Uni-t
mpn: Ut-p07a
part type: Probe
features: Passive Probe
seller oscillovectscopes:
rating: 99.7%
# reviews: 13233
city: worcester, pennsylvania
shipping oscillovectscopes:
service: economy
transit: 3-7 days
type: fixed
class: economy
payments oscillovectscopes:
wallet: paypal
other
credit card: diners-club
offer oscillovectscopes:
prices: $2699.00–$6299.00
item condition: New
sold #: 10
started: january 28, 2026
availability: in stock
options: ship-to-home
general oscillovectscopes:
category: Business & Industrial > Test, Measurement Inspection > Analyzers Data Acquisition > Oscilloscopes Vectorscopes
returns oscillovectscopes:
time: 30 days
policy: returns accepted
paid by: seller
method: money back
rating: 99.7% out of 100 based on 233 user ratings.
Similar Items:
Uni-t Ut-p33 Uni-t Differential Probe Attenuation 100 1 1000 1 Bandwidth 120mhzPlease consider troubleshooting prior to making a return request. Band width : 120MHZ. Photos are greatly appreciated. Probe attenuation: 100:1/1000:1. Differential probe, probe attenuation: 10:1/100:1, band width mhz: 120MHZ, voltage : 14KVPP, features:: probe...(January 4th, 2025)
Uni-t Ut-p36 Uni-t Differential Probe Attenuation 200 1 500 1 Bandwidth 100mhzPlease consider troubleshooting prior to making a return request. Photos are greatly appreciated. Band width : 100MHZ. Differential probe, probe attenuation: 200:1/500:1, band width mhz: 100MHZ, voltage : 560VDC PEAKAC/5600VDC peak ac, accuracy: 2%, features:: 200:1/500:1...(January 4th, 2025)
Uni-t Ut-p41 Uni-t Current Probe Voltage Output 100mv a 10mv a Max A Dc 100a FCurrent probe, voltage : output: 100MV/A, 10MV/A, max a ac: n/a, max dc: 100A, frequency: dc 100KHZ, features:: probe. Photos are greatly appreciated. Please consider troubleshooting prior to making a return request. Max current: 100A...(January 4th, 2025)
Uni-t Ut-p44 Uni-t Current Probe Voltage Output 50mv a Max 40aThey are used to measure the circuit current with an oscilloscope using electromagnetic induction and magneto-electric. The delay time of any two probes is less than 1NS.FEATURES:: current probe. Please consider troubleshooting prior to making a return request. They can be used to do power analysis ...(February 21st, 2025)
Uni-t Ut-p31 Uni-t Differential Probe Attenuation 10 1 100 1 Bandwidth 100mhzUni-t UT-P31 - differential probe, attenuation: 10:1/100:1, band width : 100MHZ, voltage : 1500VPP the is a 100MHZ differential probe.features:: probe. Please consider troubleshooting prior to making a return request. Photos are greatly appreciated...(February 21st, 2025)
Uni-t Ut-p32 Uni-t Differential Probe Attenuation 100 1 1000 1 Bandwidth 50mhzPlease consider troubleshooting prior to making a return request. Photos are greatly appreciated. voltage : 3.0KVPP. Uni-t UT-P32 - differential probe, attenuation: 100:1/1000:1, band width : 50MHZ, voltage : 3000VPP the is a 50MHZ differential probe.features:: probe attenuation: 100:1/1000:1...(February 21st, 2025)
Uni-t Ut-p40 Uni-t Current Probe Voltage 600vrms Output 50mv a 5mv a MaxPhotos are greatly appreciated. Please consider troubleshooting prior to making a return request. Uni-t UT-P40 - current probe, voltage : 600VRMS, output: 50MV/A, 5MV/A, max current: 60A, frequency: DC-100KHZ this is a dc to 100KHZ current probe.features:: probe...(February 21st, 2025)
Uni-t Ut-p42 Uni-t Current Probe Voltage Output 50mv a 5mv a Max 200aPhotos are greatly appreciated. voltage : 600VRMS. Uni-t UT-P42 - current probe, voltage output: 50MV/A, 5MV/A, max current: 200A, frequency: DC-150KHZ this is a current probe that can measure currents up to 200A.FEATURES. Please consider troubleshooting prior to making a return request...(February 21st, 2025)
Uni-t Ut-p30 Uni-t Differential Probe Attenuation 10 1 100 1 Bandwidth 100mhzPhotos are greatly appreciated. Uni-t UT-P30 - differential probe, attenuation: 10:1/100:1, band width : 100MHZ, voltage : 800VPP the is a 100MHZ differential probe.features:: probe. Please consider troubleshooting prior to making a return request...(February 24th, 2025)